Home |  Unternehmen  |  Kontakt  |  Kalender
Spacer
   
 

Food and Beverage Facility Recommendation

Select a number to view the recommendation:

Food Manufacturing

Inert Area

InertAn area in which the risk of biocontamination of the product is average or low to negligible, according to Standard ISO/ DIS 14698-1.

Examples of applications

  • Reception areas / low-temperature storage of raw materials (areas of “non-movement”).
  • Areas for packaging, cartoning and storage of pre-packed products.
  • Air-conditioned workrooms... Air quality “ventilation and air-conditioning systems must not be a source of food contamination” (Order dated 9 May 1995, Art. 3).

Sensitive Area

SensitiveAn area in which the risk of biocontamination of the product is high to average, according to Standard EN/DIS 14698-1.

Examples of applications

  • Atmosphere in slicing, carving and processing rooms.
  • Atmosphere in pre-packing rooms.
  • Maturation areas.
  • Sensitive airlock for personnel, equipment and materials...

Air quality High level of microbiological cleanness. Conditioning of atmosphere in turbulent flow in class: 10,000 to 100,000 (fed. std. 209 E), M5.5 to M6.5 (fed. std. 209 E), ISO 7 to ISO 8 (EN 14644-1), according to stage in process.

Recommended air filtration solution

HEPA H10 (EN 1822) efficiency for an average risk level, to HEPA H12 (EN 1822) for a high risk level. “SOFILAIR Green” high flow rate HEPA filtering cell. Inox stainless-steel case located as close as possible to the point of use.

Ultra Sensitive Area

Ultra-SensitiveAn area in which the risk of biocontamination of the product is very high, according to Standard ISO/DIS 14698-1.

Examples of applications

  • Carving, boning, trimming.
  • Grinding and fine-grinding areas.
  • Slicing areas.
  • Areas where food is removed from refrigeration prior to pre-packing.
  • Assembly/pre-packing Areas where fermenting agents are prepared ...

Air quality Very high level of microbiological cleanness Close protection: class 100/M3.5 (fed. std. 209 E) or ISO 5 (EN 14644-1) in laminar flow. Atmosphere: class 1000/10,000 (fed. std. 209 E) or ISO 6 / ISO 7 (EN 14644-1)

Recommended air filtration solution

High level of risk control. H14 efficiency according to Standard EN 1822. On machine and equipment: Silent Hood filter unit, MEGALAM Laminar-flow panels in SOFDISTRI diffuser case. Laminar canopies: MEGALAM laminar-flow panels mounted on CAMGRID structure. In atmosphere: Silent Hood filter unit, MEGALAM laminar-flow panels in SOFDISTRI diffuser housing or mounted on CAMGRID structure.

Hi-FloEcopleat30/3030/30MediaOpakfil / DurafilOpakfil / DurafilOpakfil GTOpakfil / DurafilOpakfil GTSofilair / Filtra 2000Stainless Steel CasingsCamsealMegalam EPTFEMegalamMolecularMolecular AdsorberEcopleatEcopleat