With this unit one gets to know the truth about how air filters work under real conditions. Different filters can be tested at the same time under the same ambient conditions, (RH%, temp, air flow, etc). for an extended period of time. There are four separate ducts. Each duct has a pre-and fine filter section and a separately controlled fan. Measured values from all filter steps, orifices, temperature and relative humidity are logged continuously. Logged values can be retrieved on site or through a wireless modem. The lab can placed anywhere and will only require an electrical connection. Four combinations of filters can be tested at the same time. The Lab can accomodate Particle, Stub and Gas measurements.